2009-03-30 12:46:14
 

APC Back-UPS RS, 720 Watts / 1200 VA,Input 230V / Output 230V Includes: CD with software, Documentation CD, Qty 2 - Detachable IEC C13 to IEC C14 power cords, Telephone Cable, USB cable.

The major advantage of this model is his integrated LCD (Liquid Crystal Display) on which can be seen more than 20 information regarding the status of the UPS, the electrical network and voltage equipment supplied by the UPS.

This product is available at Omnilogic and through Omnilogic re-sellers only for 242 euro (plus VAT). You may contact us by phone at 021 303 3119 or via email at alin.popa@omnilogic.ro.

BR1200LCDI Features Battery failure notification - Provides early-warning fault analysis on batteries enabling timely preventive maintenance Battery-protected and surge-only outlets - Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment Cold-start capable - Provides temporary battery power when the utility power is out. Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Disconnected battery notification - Warns when a battery is not available to provide backup power.

Dataline Surge Protection - Provides protection of connected equipment from power surges on the data lines. Boost Automatic Voltage Regulation (AVR) - Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery. Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced. Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible Alarms - Provides notification of changing utility power and UPS conditions. User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) USB Connectivity - Provides management of the UPS via a USB port (not available on all models). Transformer-block spaced outlets - Protect equipment with input transformer blocks without blocking access to other receptacles. Intelligent Battery Management - Maximizes battery performance, life, and reliability through intelligent, precision charging.

Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. Lifetime data recovery warranty - Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit.

Adjustable voltage sensitivity - Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications. Battery replacement without tools - Allows quick, easy battery replacement. LCD graphics display - Text and mimic diagrams that display modes of operation, system parameters and alarms.

Back-UPS RS Features & Benefits Protection Battery-protected and surge-only outlets - Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment Boost and Trim Automatic Voltage Regulation (AVR) - Gives higher application availability by correcting low and high voltage conditions without using the battery. Data line surge protection - Provides protection of connected equipment from power surges on the data lines. Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

Power conditioning - Protects connected loads from surges, spikes, lightning, and other power disturbances. Convenience Audible Alarms - Provides notification of changing utility power and UPS conditions. Automatic restart of loads after UPS shutdown - Automatically starts up the connected equipment upon the return of utility power. Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery replacement without tools - Allows quick, easy battery replacement. LED status indicators - Quickly understand unit and power status with visual indicators. Cold-start capable - Provides temporary battery power when the utility power is out. Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Resettable circuit breakers - Enables a quick recovery from overload events. Transformer-block spaced outlets - Protect equipment with input transformer blocks without blocking access to other receptacles.

User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Manageability Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Serial Connectivity - Provides management of the UPS via a serial port. USB Connectivity - Provides management of the UPS via a USB port (not available on all models). Multiple mounting methods - Allows for standardization on one product for use in different environments. Intelligent Battery Management - Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.